Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Language
Document Type
Year range
1.
Europace ; 23(SUPPL 3):iii430, 2021.
Article in English | EMBASE | ID: covidwho-1288015

ABSTRACT

Introduction: The first wave of the COVID-19 crisis was associated with a reduction of patients presenting with acute cardiovascular disease. However, there is only limited data showing the trend of pacemaker implantations and their indications. Purpose: To evaluate pacemaker implantations before, during and after the first COVID-19 wave, stratified by indication. Methods: We analysed the weekly rates of pacemaker implantation at our centre during the first national lockdown for COVID-19 at the between 16 March 2020 and 29 April 2020 (weeks 12-17 / 2020), compared to the implantation rates 6 weeks before (weeks 6-11 / 2020), 6 weeks afterwards (weeks 18-23 / 2020), and the same time frame in 2017-2019. To reduce bias due to postponed planned procedures, we stratified pacemaker implantations into the following groups: total implantations (including box changes), new pacemaker implantations, implantation due to AV block, implantation due to supraventricular conduction disturbances, and other implantations. Results: The total number of total weekly implantations was reduced from 10.7 (weeks 6-11 / 2020) to 4.2 (weeks 12-17 / 2020;-60.1%, p = 0.02). We found no significant reduction in the same time frame in 2017-2019 (6.5 vs. 6.1 per week, p = 0.29). We found a similar effect in 'new' pacemaker implantations (8.5 vs. 3.2 per week, -62.7%, p = 0.02) and AV block (5.0 vs. 1.5 per week, -70%, p = 0.03). There was no reduction in pacemaker implantation due to sick sinus syndrome (2.5 vs. 0.8 per week, -66.7%, p = 0.12) and other indications (1.0 vs. 0.8 per week, -16.7%, p = 0.86). In the six following weeks (18-23 / 2020), the total numbers (6.0 per week) and indications other than AV block rose to baseline (p > 0.05), but patients with AV block were still less prevalent (1.7 per week, p = 0.04). Conclusion: The reduction of total and new pacemaker implantations during the COVID-19 lockdown was mainly based on a reduced pacemaker implantation rate for AV block. This effect persisted even after the national lockdown. This analysis implies that a significant number of patients with AV block may have avoided medical contact during and after the lockdown and therefore have experienced increased mortality.

2.
Wiener Klinische Wochenschrift ; 132(SUPPL 5):S218-S218, 2020.
Article in English | Web of Science | ID: covidwho-938074
SELECTION OF CITATIONS
SEARCH DETAIL